NUMERICAL SIMULATION OF THE BEHAVIOR OF COLD-FORMED SHEAR CONNECTORS

  • Lívia Cristina Lopes Sousa Universidade Federal do Ceará
  • Jerfson M. Lima Universidade Federal do Ceará
  • Gregório Sandro Vieira Universidade Federal de Uberlândia
  • Jorge Bonilla Universidade de Brasília
  • Paulo Henrique Roberto Moura Universidade de Brasília
  • Eric Mateus Fernandes Bezerra Universidade de Brasília

Abstract

The shear connector is a device applied to the steel-concrete interface of composite structural elements, with the function of transferring efforts between the steel element and the concrete element, and vice versa. The U shear connector made up of a cold-formed profile is a low-cost alternative connector, however, more studies to understand its mechanical behavior need to be developed. In this sense, this work aims to numerically simulate the mechanical behavior of U-shaped shear connectors consisting of a cold-formed profile. The numerical model developed was validated with experimental tests from the literature. The results obtained were satisfactory and consistent with the experimental results, indicating that the developed model is capable of simulating the behavior of U-shaped shear connectors with a cold-formed profile.

Downloads

Download data is not yet available.

References

ABAQUS, User’s Manual, Version 6.14-4, Dessault Systèmes Simulia Corp, Providence, RI, USA, 2014.

BEZERRA, L. M.; BARBOSA, W. C. S.; BONILLA, J.; CAVALCANTE, O. R. O. Truss-type shear connector for composite steel-concrete beams. Construction and Building Materials, v. 167, p. 757–767, 2018.

DAVID, D. L. (2007). Análise teórica e experimental de conectores de cisalhamento e vigas mistas constituídas por perfis formados a frio e laje de vigotas pré-moldadas. Tese de Doutorado em Engenharia de Estruturas, Escola de Engenharia de São Carlos, Universidade de São Paulo, São Carlos, 2007.

European Committee for Standardization. Design of Composite Steel and Concrete Structures - Part 1–1: General Rules and Rules for Buildings. Eurocode 2004;4.

KIM, S. H.; PARK, S.; KIM, K. S.; JUNG, C. Y. Generalized formulation for shear resistance on Y-type perfobond rib shear connectors. Journal of Constructional Steel Research, v. 128, p. 245–260, 2017.

LIMA, J. M.; BEZERRA, L. M.; BONILLA, J.; BARBOSA, W. C. S. Study of the behavior and resistance of right-angle truss shear connector for composite steel concrete beams. Enginnering Structures, v. 235, p. 113778, 2022.

LIMA, J. M.; BEZERRA, L. M.; BONILLA, J.; SILVA, R. S. Y. R. C.; BARBOSA, W. C. S. Behavior and resistance of truss-type shear connector for composite steel-concrete beams. Steel and Composite Structures, v. 36, n. 5, p. 569–586, 2020.

NETO, J., G., R.; VIEIRA, G. S.; ZOCCOLI, R. O. Experimental analysis of the structural behavior of different types of shear connectors in steel-concrete composite beams. IBRACON Structures and Materials Journal, v. 13, n. 6, e13610, 2020.

NGUYEN, H. T.; KIM, S. E. Finite element modeling of push-out tests for large stud shear connectors. Journal of Constructional Steel Research, v. 65, n. 10–11, p. 1909–1920, 2009.

QURESHI, J.; LAM, D. Behaviour of Headed Shear Stud in Composite Beams with Profiled Metal Decking. Advances in Structural Engineering, v. 15, n. 9, p. 1547–1558, 2012.

SILVA, P. H. M. (2006). Conector de cisalhamento em perfil formado a frio: Análise via modelagem computacional. Dissertação de Mestrado em Engenharia Civil, Escola de Engenharia Civil, Universidade Federal do Goiás, Goiânia, 2006.
Published
2024-07-19
How to Cite
Sousa , L. C. L., Lima, J. M., Vieira , G. S., Bonilla, J., Moura , P. H. R., & Bezerra , E. M. F. (2024). NUMERICAL SIMULATION OF THE BEHAVIOR OF COLD-FORMED SHEAR CONNECTORS. Revista Tecnológica, 33(1), 151-159. https://doi.org/10.4025/revtecnol.v33i1.72817