A comparative study of standardized methods for calculating the resistance of concrete-filled steel tubes
Abstract
In concrete-filled steel tube (CFST) composite columns, the passive confinement effect provided by the steel tube to the concrete core is of high importance. In light of this, the present study aimed to compare, through numerical analyses, the compressive strength capacity of numerical models of concrete-filled tubular section pillars with the predictions of the main existing technical standards. To achieve this, initially, a numerical model was constructed and verified, followed by a parametric analysis involving 10 CFSTs. The parameters varied included the diameter and thickness of the circular profile, the steel ratio, and the unbraced length. It was observed that as the D/t ratio of CFSTs increased, there was a lower percentage divergence between the strengths of the analytical models and that of the numerical model. This was attributed to the reduction of the confinement effect caused by the increased D/t ratio. Some standards provided predictions of strength capacity higher than that of the numerical model, although the greatest discrepancy was only 7%.
Downloads
References
ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS (ABNT). NBR 8800: Projeto de estruturas de aço e de estruturas mistas de aço e concreto de edifícios. Rio de Janeiro, 2008.
AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). AISC 360‐22: Specification for Structural Steel Buildings. Chigado, Illinois, 2022.
AZEVEDO, V. S. Avaliação experimental de colunas CFST curtas com núcleo de concreto reciclado. 2018. 238f. Tese (Doutorado em Engenharia Civil) – Faculdade de Engenharia, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2018.
CARRAZEDO, R. Mecanismos de confinamento e suas implicações no reforço de pilares de compósito de fibras de carbono. São Carlos, 2002. Dissertação (Mestrado em Engenharia de Estruturas), Universidade de São Paulo, São Carlos.
CARREIRA, D. J.; CHU, K. H. Stress-Strain Relationship for Plain Concrete in Compression. ACI Journal Proceedings, v. 82, n. 6, p. 797–804, 1985.
CEN – EUROPEAN COMMITTEE FOR STANDARDIZATION. EN 1994–1–1: Design of composite steel and concrete structures - Part 1-1: General rules and rules for buildings. Brussels, 2005.
Dassault Systèmes Simulia. Abaqus 6.13. 2016.
DBJ/T 13-51-2010. Technical Specifications for Concrete-Filled Steel Tubular Structures. Fuzhou, 2010.
DE NARDIN, S. Estudo teórico - experimental de pilares mistos compostos por tubos de aço preenchidos com concreto de alta resistência. 1999. Dissertação (Mestrado em Engenharia de Estruturas). Universidade de São Paulo, São Carlos, 1999.
GENIKOMSOU, Aikaterini S.; POLAK, Maria Anna. Finite element analysis of punching shear of concrete slabs using damaged plasticity model in ABAQUS. Engineering structures, v. 98, p. 38-48, 2015.
GERIN, M. T. Comportamento de pilares mistos preenchidos com concreto de resíduos de concreto submetidos a compressão axial centrada: efeito do teor de substituição e da forma de aplicação da força. 2020. 151p. Dissertação (Mestrado em Engenharia Civil), Universidade Federal de São Carlos, São Carlos, 2020.
GOURLEY, B. C.; TORT, C.; HAJJAR, J. F.; SCHILLER, P. H. A synopsis of studies of the monotonic and cyclic behavior of concrete-filled steel tube members, connections, and frames. NSEL Report Series. Report N°. NSEL-008, p. 371, Abril, 2008. Department of Civil and Environmental Engineering. University of Illinois at Urbana-Champaign, 2008.
GUPTA, P. K.; SARDA, S. M.; KUMAR, M. S. Experimental and computational study of concrete filled steel tubular columns under axial loads. Journal of Constructional Steel Research. v. 63, n. 2, p. 182-193, 2007.
HAN, L.; LI, W.; BJORHOVDE, R. Developments and advanced applications of concrete-filled steel tubular (CFST) structures: Members. Journal of Constructional Steel Research, v. 100, p. 211-228, 2014.
OLIVEIRA, W. L. A. Análise teórico-experimental de pilares mistos preenchidos de seção circular. 2008. 251 f. Tese (Doutorado em Engenharia Civil). Escola de Engenharia de São Carlos – Programa de Pós-Graduação em Engenharia Civil, Universidade de São Paulo, 2008.
OLIVEIRA, W. L. A; DE NARDIN, S.; EL DEBS, A. L. H. C. Dimensionamento de pilares preenchidos de seção circular submetidos à compressão simples, segundo a NBR 8800:2008 e Eurocode 4:2004: comparação com resultados experimentais. Revista Escola de Minas. Outo Preto. v. 62, n. 31, p. 73-85, 2009.
PATHIRANA, S. W.; UY, B.; MIRZA, O.; Wijesiri et al. Flexural behaviour of composite steel– concrete beams utilising blind bolt shear connectors. Engineering Structures, v. 114, p. 181- 194, 2016.
YU, T.; TENG; J. G.; WONG, Y. L.; DONG, S. L.. Finite element modeling of confined concrete-II: Plastic-damage model. Engineering structures, v. 32, n. 3, p. 680-691, 2010.
Os autores podem manter os direitos autorais pelo seu trabalho, mas repassam direitos de primeira publicação à revista. A revista poderá usar o trabalho para fins não-comerciais, incluindo direito de enviar o trabalho em bases de dados de Acesso Livre.