Dynamic experimental analysis of a LiBr/H2O single effect absorption chiller with nominal capacity of 35 kW of cooling

Autores

  • Alvaro Antonio Ochoa Villa Instituto Federal de Pernambuco http://orcid.org/0000-0003-1687-8523
  • José Carlos Charamba Dutra Instituto Federal de Tecnologia de Pernambuco / Universidade Federal de Pernambuco
  • Jorge Recarte Henrí­quez Henrí­quez Universidade Federal de Pernambuco
  • Carlos Antonio Cabral do Santos Universidade Federal de Pernambuco / Universidade Federal da Paraí­ba
  • José í‚ngelo Peixoto da Costa Instituto Federal de Tecnologia de Pernambuco / Universidade Federal de Pernambuco

DOI:

https://doi.org/10.4025/actascitechnol.v41i1.35173

Palavras-chave:

Comportamento energético, Solução de Brometo de Lí­tio/Ígua, carga térmica, COP.

Resumo

This work aims to transient performance of chiller single effect absorption refrigeration using the LiBr/H2O pair with nominal capacity of 35 kW. The goal of this study is to verify the absorption chiller when subjected to thermal loads and it transiently responsive as a function of the temperatures of the chilled, hot and cold water of the system. An experimental methodology was established in a micro-CHP laboratory to simulate the dynamic operating conditions of the system considering the thermal load (chilled water), the activation source (hot water) and the heat dissipation circuit (cold water). The thermal load was simulated from a set of electrical resistors installed in a water heater and the activation of the chiller from recovery gas a microturbine 30 kW and through a compact heat exchanger, where water is heated and stored in a hot buffer tank. The absorption chiller heat dissipation system consists of the pump and cooling tower. The system responded appropriately to the thermal load imposed providing COP values in the transient regime of 0.55 to 0.70 the temperature conditions tested.

Downloads

Não há dados estatísticos.

Biografia do Autor

Alvaro Antonio Ochoa Villa, Instituto Federal de Pernambuco

Prof. Refrigeração e Climatização - DACI - Campus Recife. IFPE

Írea: Energia

Downloads

Publicado

2019-05-02

Como Citar

Villa, A. A. O., Dutra, J. C. C., Henrí­quez, J. R. H., Santos, C. A. C. do, & Costa, J. í‚ngelo P. da. (2019). Dynamic experimental analysis of a LiBr/H2O single effect absorption chiller with nominal capacity of 35 kW of cooling. Acta Scientiarum. Technology, 41(1), e35173. https://doi.org/10.4025/actascitechnol.v41i1.35173

Edição

Seção

Engenharia Mecânica

 

0.8
2019CiteScore
 
 
36th percentile
Powered by  Scopus

 

 

0.8
2019CiteScore
 
 
36th percentile
Powered by  Scopus

Artigos mais lidos pelo mesmo(s) autor(es)