Comparison of the TDR and ECHO systems to measure soil moisture, in a clayey soil and in sand - DOI: 10.4025/actasciagron.v26i3.1841

Authors

  • Marcos Antonio Trintinalha UEM Author
  • Antônio Carlos Andrade Gonçalves Engenharia Rural - UEM Author
  • Cassio Antonio Tormena UEM Author
  • Antonio Carlos Saraiva da Costa UEM Author
  • Marcos Vinicius Folegatti USP Author
  • Paulo Sergio Lourenço de Freitas UEM Author
  • Roberto Rezende UEM Author

DOI:

https://doi.org/10.4025/actasciagron.v26i3.1841

Keywords:

TDR, umidade do solo, ECHO, calibração

Abstract

TDR technique has been intensively applied around the world to measure volumetric soil water content. Although its good results, this system is rather expensive. Other systems have been developed to measure soil dielectric constant or electric potential under lower cost conditions. ECHO system has been used on some soil conditions with good results. For tropical soils conditions, there is no investigation about its application. This work was carried out to evaluate TDR and ECHO applications on a tropical soil Typic Paleudalf, which presents 73% of clay, commonly found at the Northeast region of Paraná, Brazil, and on a “washed sand” material. Mathematic models were fit, by linear regression analyses, to describe relations between soil volumetric water content and apparent soil dielectric constant (Ka) and between soil volumetric water content and electric potential. Results showed that both equipments can be used to adequately estimate soil water content, since careful calibrations were done before use

Downloads

Download data is not yet available.

Author Biography

  • Antônio Carlos Andrade Gonçalves, Engenharia Rural - UEM
    Possui graduação em Engenharia Agrícola pela Universidade Federal de Viçosa (1984) , mestrado em Engenharia Agrícola pela Universidade Federal de Viçosa (1987) e doutorado em Agronomia pela Escola Superior de Agricultura Luiz de Queiroz (1997) . Atualmente é Professor Adjunto da Universidade Estadual de Maringá. Tem experiência na área de Engenharia Agrícola , com ênfase em Engenharia de Ãgua e Solo. Atuando principalmente nos seguintes temas: variabilidade espacial, pivô-central, irrigação, geoestatística, retenção de água no solo. Currículo Lattes

Published

2008-04-11

Issue

Section

Agronomy

How to Cite

Trintinalha, M. A., Gonçalves, A. C. A., Tormena, C. A., Costa, A. C. S. da, Folegatti, M. V., Freitas, P. S. L. de, & Rezende, R. (2008). Comparison of the TDR and ECHO systems to measure soil moisture, in a clayey soil and in sand - DOI: 10.4025/actasciagron.v26i3.1841. Acta Scientiarum. Agronomy, 26(3), 353-360. https://doi.org/10.4025/actasciagron.v26i3.1841

Similar Articles

1-10 of 518

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)

<< < 1 2 3 4 5 6 7 8 > >>